Input voltage: 5 V (4.5V-9V) 12V (9V-18V) 24V (18V-36V) 48V (36V-72V)
110V (80V-180V) 300V (200V-400V) 600V (400V-800V)
9-36V 8-80V 18-48V 16-160V 10 times wide range input
Output Voltage: 1.8 V-48VDC
Output power :5-2000 W
Voltage accuracy: ± 1%
Conversion efficiency: ≥ 85%
Ripple (Vp-p): ≤ 1% For lower ripple I can phone company
MTBF (mean time between failure): 500,000 hours
Voltage adjustment rate: ± 0.2% (Main Road)
Load regulation of: ± 0.4% (Main Road)
Temperature regulation rate: ± 0.01% / ℃
Current restrictions: 120%
Transient response: 200 uS
Isolation resistance: 200 M Ω
Isolation voltage: Enter - Shell 1500 VDC input - output 1050 VDC output - 500 VDC output
Shell-work: -40 - +85 ℃ (Army I) -55 - +85 ℃ (Army II) category brick module maximum temperature up to 100 ℃
Storage temperature: -55 - +105 ℃
Humidity: 20-90% RH (non-condensing) 0-11Km (troposphere) - military targets
Storage humidity: 10-95% RH (non-condensing) 0-11Km (troposphere) - military targets
Shock and vibration
10-55 Hz 5G vibration amplitude of 0.35 mm X, Y, Z three directions each 30 minutes
Impact (half-sine) 30G standard pulse width of 11 ms X, Y, Z three directions of the six times
Electromagnetic Compatibility
Conduction and radiation: built-in differential mode, the common mode interference suppression circuit
The adoption of effective suppression circuit, and to take measures to improve the shielding
Protection: over-current protection, short-circuit protection, thermal protection, over-voltage protection (optional)
Anti-salt spray, anti-humidity and anti-mold, dust |
|
|
|
|